  • Model 2051L

    Measurement Type: Differential, Gauge, Absolute, Level and Flow
    Product Configurations: 2051L with flush and extended diaphragm seals 1199 Diaphragm Seal optional.
    Long Term Stability: 0.1% of URL for 2 years
    Output: 4-20mA HART®, FOUNDATION™ fieldbus, 1-5Vdc HART Low Power
    Reference Accuracy: 0.075% of span
    Rangedown: 100:1

    Data sheet
  • Model 3050SL

    Measurement Type: Differential and gage level measurement
    Product Configurations: 3051S_L with flush and extended diaphragm seals 1199 Remote Seal optional
    Output: 4-20mA HART™, FOUNDATION™ fieldbus, WirelessHART™
    Reference Accuracy: 0.065% of span
    Rangedown: 100:1
    Warranty: Up to 12-year limited warranty

    Data sheet
  • Model 3050L

    Measurement Type: Differential and gage level measurement
    Product Configurations: 3051L with flush and extended diaphragm seals. 1199 Diaphragm Seal optional.
    Output: 4-20mA HART™, FOUNDATION™ fieldbus, Profibu PA, 1-5Vdc HART Low Power.
    Reference Accuracy: 0.075% of span
    Rangedown: 100:1

    Data sheet
  • Model 2090F

    Measurement Types: Gage, Absolute
    Output: HART
    Reference Accuracy: ± 0.20% of Span
    Stability: ± 0.10% of URL for 12 months
    Rangedown: 20:1

    Data sheet
  • Model 2090P

    Measurement Types: Gage, Absolute
    Output: HART
    Reference Accuracy: ± 0.20% of Span
    Stability: ± 0.10% of URL for 12 months
    Rangedown: 20:1

    Data sheet
  • Model 2088

    Measurement Types: Gauge, Absolute
    Output: HART, Low Power HART
    Reference Accuracy:
      ± 0.075% of span
      ± 0.065% of span
    Stability: ± 0.10% or URL for 3 years

    Data sheet
  • Model 2051

    Measurement Type: Differential, Gage, Absolute, Level, Flow
    Output: 4-20mA HART®, FOUNDATION™ fieldbus, PROFIBUS PA, 1-5Vdc HART® Low Power Wireless™, WirelessHART™
    Reference Accuracy:
      ± 0.065% of span
      ± 0.05% of span
    Long Term Stability:
      ± 0.1% of URL for 2 years
      ± 0.125% of URL for 5 years
    Rangedown:100:1

    Data sheet
  • Model 3051

    Measurement Type: Differential, Gage, Absolute, Level, Flow
    Output: 4-20mA HART (Revision 5), FOUNDATION™ Fieldbus, PROFIBUS PA
    Reference Accuracy:
      0.065% of span
      0.04% of span (with high accuracy option)
    Total Performance: + 0.15%ofspan
    Long Term Stability: + 0.125% of URL for 5 years
    Rangedown: 100:1

    Data sheet
  • Model 3051S

    Measurement Type: Differential, gage, absolute, and multivariable pressure
    Output: HART®, WirelessHART™, FOUNDATION™ fieldbus
    Reference Accuracy: ±0.025% of span
    Total Performance: ±0.1% of span
    Rangedown: 200:1

    Data sheet